2011•Annals of Noninvasive ElectrocardiologyOpen access

Highly Automated QT Measurement Techniques in 7 Thorough QT Studies Implemented under ICH E14 Guidelines

Jean‐Philippe Couderc, Christine E. Garnett, Mike Li, Robert M. Handzel, Scott A McNitt, Xiajuan Xia, Slava Polonsky, Wojciech Zaręba

Open full text 36 citations

Abstract

Thorough QT (TQT) studies are designed to evaluate potential effect of a novel drug on the ventricular repolarization process of the heart using QTc prolongation as a surrogate marker for torsades de pointes. The current process to measure the QT intervals from the thousands of electrocardiograms is lengthy and expensive. In this study, we propose a validation of a highly automatic-QT interval measurement (HA-QT) method. We applied a HA-QT method to the data from 7 TQT studies. We investigated both the placebo and baseline-adjusted QTc interval prolongation induced by moxifloxacin (positive control drug) at the time of expected peak concentration. The comparative analysis evaluated the time course of moxifloxacin-induced QTc prolongation in one study as well. The absolute HA-QT data were longer than the FDA-approved QTc data. This trend was not different between ECGs from the moxifloxacin and placebo arms: 9.6 ± 24 ms on drug and 9.8 ± 25 ms on placebo. The difference between methods vanished when comparing the placebo-baseline-adjusted QTc prolongation (1.4 ± 2.8 ms, P = 0.4). The differences in precision between the HA-QT and the FDA-approved measurements were not statistically different from zero: 0.1 ± 0.1 ms (P = 0.7). Also, the time course of the moxifloxacin-induced QTc prolongation adjusted for placebo was not statistically different between measurements methods.

About this research paper

What this paper is about

Thorough QT (TQT) studies are designed to evaluate potential effect of a novel drug on the ventricular repolarization process of the heart using QTc prolongation as a surrogate marker for torsades de pointes. The current process to measure the QT intervals from the thousands of electrocardiograms is lengthy and expensive. In this study, we propose a validation of a highly automatic-QT interval measurement (HA-QT) method. We applied a HA-QT method to the data from 7 TQT studies. We investigated both the placebo and baseline-adjusted QTc interval prolongation induced by moxifloxacin (positive control drug) at the time of expected peak concentration. The comparative analysis evaluated the time course of moxifloxacin-induced QTc prolongation in one study as well. The absolute HA-QT data were longer than the FDA-approved QTc data. This trend was not different between ECGs from the moxifloxacin and placebo arms: 9.6 ± 24 ms on drug and 9.8 ± 25 ms on placebo. The difference between methods vanished when comparing the placebo-baseline-adjusted QTc prolongation (1.4 ± 2.8 ms, P = 0.4). The differences in precision between the HA-QT and the FDA-approved measurements were not statistically different from zero: 0.1 ± 0.1 ms (P = 0.7). Also, the time course of the moxifloxacin-induced QTc prolongation adjusted for placebo was not statistically different between measurements methods.

Why it matters

OpenAlex reports 36 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Thorough QT (TQT) studies are designed to evaluate potential effect of a novel drug on the ventricular repolarization process of the heart using QTc prolongation as a surrogate marker for torsades de pointes. The current process to measure the QT intervals from the thousands of electrocardiograms is lengthy and expensive. In this study, we propose a validation of a highly automatic-QT interval measurement (HA-QT) method. We applied a HA-QT method to the data from 7 TQT studies. We investigated both the placebo and baseline-adjusted QTc interval prolongation induced by moxifloxacin (positive control drug) at the time of expected peak concentration. The comparative analysis evaluated the time course of moxifloxacin-induced QTc prolongation in one study as well. The absolute HA-QT data were longer than the FDA-approved QTc data. This trend was not different between ECGs from the moxifloxacin and placebo arms: 9.6 ± 24 ms on drug and 9.8 ± 25 ms on placebo. The difference between methods vanished when comparing the placebo-baseline-adjusted QTc prolongation (1.4 ± 2.8 ms, P = 0.4). The differences in precision between the HA-QT and the FDA-approved measurements were not statistically different from zero: 0.1 ± 0.1 ms (P = 0.7). Also, the time course of the moxifloxacin-induced QTc prolongation adjusted for placebo was not statistically different between measurements methods.

Key concepts: QT interval, Moxifloxacin, Medicine, Placebo, Torsades de pointes, Prolongation, Internal medicine, Cardiology

Related papers

Back to paper searchBrowse research topicsOriginal source
Highly Automated QT Measurement Techniques in 7 Thorough QT Studies Implemented under ICH E14 Guidelines — Research Paper | ScholarLens