Advanced heart block during acute myocardial infarction treated with an electrode pacing catheter.

Dwight I. Peretz

Open full text 5 citations

Abstract

The mortality rate is high from advanced atrioventricular block associated with acute myocardial infarction. There is reason to believe that if in these patients the hearts are electrically paced with an endocardial pacing catheter, the mortality rate can be considerably decreased. Five patients in second- and third-degree heart block associated with acute myocardial infarction were paced with a considerable lowering of the expected mortality rate. Twenty-three cases from the literature are also presented and discussed. A silastic bipolar electrode catheter was used in these five cases. Four of the five cases returned to normal sinus rhythm within the first 10 days. The average duration of pacing was 6.7 days. It is the opinion of the author that second- and third-degree heart block associated with acute myocardial infarction should have a pacing catheter introduced at the earliest possible moment for continuous or demand endocardial pacing.

About this research paper

What this paper is about

The mortality rate is high from advanced atrioventricular block associated with acute myocardial infarction. There is reason to believe that if in these patients the hearts are electrically paced with an endocardial pacing catheter, the mortality rate can be considerably decreased. Five patients in second- and third-degree heart block associated with acute myocardial infarction were paced with a considerable lowering of the expected mortality rate. Twenty-three cases from the literature are also presented and discussed. A silastic bipolar electrode catheter was used in these five cases. Four of the five cases returned to normal sinus rhythm within the first 10 days. The average duration of pacing was 6.7 days. It is the opinion of the author that second- and third-degree heart block associated with acute myocardial infarction should have a pacing catheter introduced at the earliest possible moment for continuous or demand endocardial pacing.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The mortality rate is high from advanced atrioventricular block associated with acute myocardial infarction. There is reason to believe that if in these patients the hearts are electrically paced with an endocardial pacing catheter, the mortality rate can be considerably decreased. Five patients in second- and third-degree heart block associated with acute myocardial infarction were paced with a considerable lowering of the expected mortality rate. Twenty-three cases from the literature are also presented and discussed. A silastic bipolar electrode catheter was used in these five cases. Four of the five cases returned to normal sinus rhythm within the first 10 days. The average duration of pacing was 6.7 days. It is the opinion of the author that second- and third-degree heart block associated with acute myocardial infarction should have a pacing catheter introduced at the earliest possible moment for continuous or demand endocardial pacing.

Key concepts: Medicine, Myocardial infarction, Catheter, Atrioventricular block, Cardiology, Heart block, Internal medicine, Infarction

Related papers

Back to paper searchBrowse research topicsOriginal source
Advanced heart block during acute myocardial infarction treated with an electrode pacing catheter. — Research Paper | ScholarLens