2014•Biomedical ChromatographyRequires access

Quantification of heteroclitin D in rat plasma: validation of an LC/MS/MS method and its application in a preclinical pharmacokinetic study

Fan Zhang, Nan Zhang, Li Pang, Yan Tan, Hong‐Xi Xu

Open publisher page 3 citations

Abstract

A rapid, sensitive and specific liquid chromatography tandem mass spectrometry (LC/MS/MS) method was developed and validated for the quantification of heteroclitin D in rat plasma after using gambogic acid as internal standard (IS). Chromatographic separation was done on a Thermo Hypersil GOLD column (30 × 2.1 mm, 3 µm) using a mobile phase consisting of methanol-water-formic acid (80:20:0.1, v/v/v). The mass spectrometer worked with positive electrospray ionization in multiple reaction monitoring mode, using target ions at [M + H](+) m/z 483.3 for heteroclitin D and [M + H](+) m/z 629.3 for the IS. The standard curve was linear (R(2) ≥0.995) over the concentration range 9.98-2080 ng/mL and had good back-calculated accuracy and precision. The intra- and interday precision and accuracy determined on three quality control samples (29.94, 166.4 and 1872 ng/mL) were ≤12.8 and -8.9-3.6%, respectively. The extraction recovery was ≥88.2% and the lower limit of quantification was 9.98 ng/mL. The method was successfully applied to evaluate pharmacokinetics of heteroclitin D in Sprague-Dawley rats following a single intravenous bolus injection of 2.0 mg/kg heteroclitin.

About this research paper

What this paper is about

A rapid, sensitive and specific liquid chromatography tandem mass spectrometry (LC/MS/MS) method was developed and validated for the quantification of heteroclitin D in rat plasma after using gambogic acid as internal standard (IS). Chromatographic separation was done on a Thermo Hypersil GOLD column (30 × 2.1 mm, 3 µm) using a mobile phase consisting of methanol-water-formic acid (80:20:0.1, v/v/v). The mass spectrometer worked with positive electrospray ionization in multiple reaction monitoring mode, using target ions at [M + H](+) m/z 483.3 for heteroclitin D and [M + H](+) m/z 629.3 for the IS. The standard curve was linear (R(2) ≥0.995) over the concentration range 9.98-2080 ng/mL and had good back-calculated accuracy and precision. The intra- and interday precision and accuracy determined on three quality control samples (29.94, 166.4 and 1872 ng/mL) were ≤12.8 and -8.9-3.6%, respectively. The extraction recovery was ≥88.2% and the lower limit of quantification was 9.98 ng/mL. The method was successfully applied to evaluate pharmacokinetics of heteroclitin D in Sprague-Dawley rats following a single intravenous bolus injection of 2.0 mg/kg heteroclitin.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A rapid, sensitive and specific liquid chromatography tandem mass spectrometry (LC/MS/MS) method was developed and validated for the quantification of heteroclitin D in rat plasma after using gambogic acid as internal standard (IS). Chromatographic separation was done on a Thermo Hypersil GOLD column (30 × 2.1 mm, 3 µm) using a mobile phase consisting of methanol-water-formic acid (80:20:0.1, v/v/v). The mass spectrometer worked with positive electrospray ionization in multiple reaction monitoring mode, using target ions at [M + H](+) m/z 483.3 for heteroclitin D and [M + H](+) m/z 629.3 for the IS. The standard curve was linear (R(2) ≥0.995) over the concentration range 9.98-2080 ng/mL and had good back-calculated accuracy and precision. The intra- and interday precision and accuracy determined on three quality control samples (29.94, 166.4 and 1872 ng/mL) were ≤12.8 and -8.9-3.6%, respectively. The extraction recovery was ≥88.2% and the lower limit of quantification was 9.98 ng/mL. The method was successfully applied to evaluate pharmacokinetics of heteroclitin D in Sprague-Dawley rats following a single intravenous bolus injection of 2.0 mg/kg heteroclitin.

Key concepts: Chemistry, Pharmacokinetics, Chromatography, Plasma, Pharmacology, Medicine, Physics, Quantum mechanics

Related papers

Back to paper searchBrowse research topicsOriginal source
Quantification of heteroclitin D in rat plasma: validation of an LC/MS/MS method and its application in a preclinical pharmacokinetic study — Research Paper | ScholarLens