Quantification of heteroclitin D in rat plasma: validation of an LC/MS/MS method and its application in a preclinical pharmacokinetic study
Fan Zhang, Nan Zhang, Li Pang, Yan Tan, Hong‐Xi Xu
Abstract
Fan Zhang, Nan Zhang, Li Pang, Yan Tan, Hong‐Xi Xu
Abstract
A rapid, sensitive and specific liquid chromatography tandem mass spectrometry (LC/MS/MS) method was developed and validated for the quantification of heteroclitin D in rat plasma after using gambogic acid as internal standard (IS). Chromatographic separation was done on a Thermo Hypersil GOLD column (30 × 2.1 mm, 3 µm) using a mobile phase consisting of methanol-water-formic acid (80:20:0.1, v/v/v). The mass spectrometer worked with positive electrospray ionization in multiple reaction monitoring mode, using target ions at [M + H](+) m/z 483.3 for heteroclitin D and [M + H](+) m/z 629.3 for the IS. The standard curve was linear (R(2) ≥0.995) over the concentration range 9.98-2080 ng/mL and had good back-calculated accuracy and precision. The intra- and interday precision and accuracy determined on three quality control samples (29.94, 166.4 and 1872 ng/mL) were ≤12.8 and -8.9-3.6%, respectively. The extraction recovery was ≥88.2% and the lower limit of quantification was 9.98 ng/mL. The method was successfully applied to evaluate pharmacokinetics of heteroclitin D in Sprague-Dawley rats following a single intravenous bolus injection of 2.0 mg/kg heteroclitin.
OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A rapid, sensitive and specific liquid chromatography tandem mass spectrometry (LC/MS/MS) method was developed and validated for the quantification of heteroclitin D in rat plasma after using gambogic acid as internal standard (IS). Chromatographic separation was done on a Thermo Hypersil GOLD column (30 × 2.1 mm, 3 µm) using a mobile phase consisting of methanol-water-formic acid (80:20:0.1, v/v/v). The mass spectrometer worked with positive electrospray ionization in multiple reaction monitoring mode, using target ions at [M + H](+) m/z 483.3 for heteroclitin D and [M + H](+) m/z 629.3 for the IS. The standard curve was linear (R(2) ≥0.995) over the concentration range 9.98-2080 ng/mL and had good back-calculated accuracy and precision. The intra- and interday precision and accuracy determined on three quality control samples (29.94, 166.4 and 1872 ng/mL) were ≤12.8 and -8.9-3.6%, respectively. The extraction recovery was ≥88.2% and the lower limit of quantification was 9.98 ng/mL. The method was successfully applied to evaluate pharmacokinetics of heteroclitin D in Sprague-Dawley rats following a single intravenous bolus injection of 2.0 mg/kg heteroclitin.
Key concepts: Chemistry, Pharmacokinetics, Chromatography, Plasma, Pharmacology, Medicine, Physics, Quantum mechanics