Influence of thermal and resonance neutron on fast neutron flux measurement by 239pu fission chamber

曾丽娜, Qiang Wang, 宋凌莉, 郑春

Open publisher page 0 citations

Abstract

The 239Pu fission chambers are widely used to measure fission spectrum neutron flux due to a flat response to fast neutrons. However,in the meantime the resonance and thermal neutrons can cause a significant influence on the measurement if they are moderated,which could be eliminated by using10 B and Cd covers. At a column enriched uranium fast neutron critical assembly,the fission reaction rates of 239 Pu are measured as 1.791×10-16,2.350×10-16 and 1.385×10-15 per second for 15 mm thick10 B cover,0.5 mm thick Cd cover,and no cover respectively,while the fission reaction rate of 239 Pu is rapidly increased to 2.569×10-14 for a 20 mm thick polythene covering fission chamber. The average 239 Pu fission cross-section of thermal and resonance neutrons is calculated to be 500 b and24.95 b with the assumption of 1/v and 1/E spectra respectively,then thermal,resonance and fast neutron flux are achieved to be 2.30×106,2.24×106 and 1.04×108cm-2·s-1.

About this research paper

What this paper is about

The 239Pu fission chambers are widely used to measure fission spectrum neutron flux due to a flat response to fast neutrons. However,in the meantime the resonance and thermal neutrons can cause a significant influence on the measurement if they are moderated,which could be eliminated by using10 B and Cd covers. At a column enriched uranium fast neutron critical assembly,the fission reaction rates of 239 Pu are measured as 1.791×10-16,2.350×10-16 and 1.385×10-15 per second for 15 mm thick10 B cover,0.5 mm thick Cd cover,and no cover respectively,while the fission reaction rate of 239 Pu is rapidly increased to 2.569×10-14 for a 20 mm thick polythene covering fission chamber. The average 239 Pu fission cross-section of thermal and resonance neutrons is calculated to be 500 b and24.95 b with the assumption of 1/v and 1/E spectra respectively,then thermal,resonance and fast neutron flux are achieved to be 2.30×106,2.24×106 and 1.04×108cm-2·s-1.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The 239Pu fission chambers are widely used to measure fission spectrum neutron flux due to a flat response to fast neutrons. However,in the meantime the resonance and thermal neutrons can cause a significant influence on the measurement if they are moderated,which could be eliminated by using10 B and Cd covers. At a column enriched uranium fast neutron critical assembly,the fission reaction rates of 239 Pu are measured as 1.791×10-16,2.350×10-16 and 1.385×10-15 per second for 15 mm thick10 B cover,0.5 mm thick Cd cover,and no cover respectively,while the fission reaction rate of 239 Pu is rapidly increased to 2.569×10-14 for a 20 mm thick polythene covering fission chamber. The average 239 Pu fission cross-section of thermal and resonance neutrons is calculated to be 500 b and24.95 b with the assumption of 1/v and 1/E spectra respectively,then thermal,resonance and fast neutron flux are achieved to be 2.30×106,2.24×106 and 1.04×108cm-2·s-1.

Key concepts: Fission, Neutron temperature, Neutron, Fast fission, Neutron flux, Nuclear physics, Resonance (particle physics), Uranium-235

Related papers

Back to paper searchBrowse research topicsOriginal source
Influence of thermal and resonance neutron on fast neutron flux measurement by 239pu fission chamber — Research Paper | ScholarLens