1999AIP conference proceedingsRequires access

Comparison of time required to charge a battery in a stand-alone photovoltaic system using different charge-controller types

P. McNutt

Open publisher page 1 citations

Abstract

An experiment was conducted at the National Renewable Energy Laboratory (NREL) comparing the time required to charge a fully discharged valve-regulated lead-acid battery in a photovoltaic (PV) system using on/off-shunt and pulse-width-modulated (PWM) charge controllers. In one system configuration, an on/off-shunt charge controller was only able to charge the battery to 61% of its rated capacity after 16 days. In a subsequent test, a different on/off-shunt controller in a different PV system configuration readily charged its battery to 100% rated capacity in less than 6 days. It charged its battery as quickly as a couple different PWM charge controllers did in identical systems in a side-by-side comparison.

About this research paper

What this paper is about

An experiment was conducted at the National Renewable Energy Laboratory (NREL) comparing the time required to charge a fully discharged valve-regulated lead-acid battery in a photovoltaic (PV) system using on/off-shunt and pulse-width-modulated (PWM) charge controllers. In one system configuration, an on/off-shunt charge controller was only able to charge the battery to 61% of its rated capacity after 16 days. In a subsequent test, a different on/off-shunt controller in a different PV system configuration readily charged its battery to 100% rated capacity in less than 6 days. It charged its battery as quickly as a couple different PWM charge controllers did in identical systems in a side-by-side comparison.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

An experiment was conducted at the National Renewable Energy Laboratory (NREL) comparing the time required to charge a fully discharged valve-regulated lead-acid battery in a photovoltaic (PV) system using on/off-shunt and pulse-width-modulated (PWM) charge controllers. In one system configuration, an on/off-shunt charge controller was only able to charge the battery to 61% of its rated capacity after 16 days. In a subsequent test, a different on/off-shunt controller in a different PV system configuration readily charged its battery to 100% rated capacity in less than 6 days. It charged its battery as quickly as a couple different PWM charge controllers did in identical systems in a side-by-side comparison.

Key concepts: Charge controller, Photovoltaic system, Lead–acid battery, Shunt (medical), State of charge, Pulse-width modulation, Battery (electricity), Renewable energy

Related papers

Back to paper searchBrowse research topicsOriginal source
Comparison of time required to charge a battery in a stand-alone photovoltaic system using different charge-controller types — Research Paper | ScholarLens