1997Pharmacotherapy The Journal of Human Pharmacology and Drug TherapyOpen access

Is the Volume of Distribution of Digoxin Reduced in Patients with Renal Dysfunction? Determining Digoxin Pharmacokinetics by Fluorescence Polarization Immunoassay

Judy W.M. Cheng, Scott L. Charland, Leslie M. Shaw, Sidney Kobrin, Stanley Goldfarb, Eric J. Stanek, Sarah A. Spinier

Open full text 34 citations

Abstract

STUDY OBJECTIVE: To determine digoxin pharmacokinetics in subjects with different degrees of renal function using fluorescence polarization immunoassay (FPIA), which is associated with less interference from digoxin-like immunoreactive substances (DLIS) than radioimmunoassay. SETTING: University hospital clinical research center. PARTICIPANTS: Eighteen subjects (mean age 44 yrs) with different degrees of renal function: group 1, creatinine clearance (Clcr) below 10 ml/minute; group 2, Clcr 10-50 ml/minute; and group 3, Clcr greater than 50 ml/minute (6 patients in each group). INTERVENTION: Over 5-7 days, 15 serum samples were collected after a single intravenous dose of digoxin 7 or 10 micrograms/kg actual body weight (WT) for serum concentration measurements by FPIA. Two-compartment pharmacokinetic parameters (zero-time intercept of the concentration-time curve of the initial distribution phase [A], zero-time intercept of the concentration-time curve of the terminal elimination phase [B], initial distribution phase constant [alpha], terminal elimination rate constant [beta], volume of distribution in the central compartment [Vc] and at steady state [Vss], total body clearance [Cl], mean residence time [MRT], area under the concentration-time curve [AUC]) were determined using a nonlinear least squares regression program. MEASUREMENTS AND MAIN RESULTS: No significant differences were found among groups for A, B, alpha, beta, beta-half-life Vc/WT, MRT, AUC, and Cl/WT. Significant differences were observed in Vss/WT (4.8 +/- 1.0, 6.6 +/- 0.5, 6.4 +/- 0.7 L/kg) between group 1 versus group 2 and group 1 versus group 3 (p < 0.01). Measured Clcr was correlated with Cl (r2 = 0.40, p < 0.01), Cl/WT (r2 = 0.29, p < 0.05), Vss (r2 = 0.35, p = 0.01), and Vss/WT (r2 = 0.24, p < 0.05). CONCLUSION: This study confirmed that Vss is smaller in patients with chronic renal failure (Clcr < 10 ml/min) than those without chronic renal failure. Therefore, previous recommendations that lower digoxin loading doses should be administered in patients with renal failure are applicable to digoxin serum concentration monitoring using FPIA.

Open-access reader

About this research paper

What this paper is about

STUDY OBJECTIVE: To determine digoxin pharmacokinetics in subjects with different degrees of renal function using fluorescence polarization immunoassay (FPIA), which is associated with less interference from digoxin-like immunoreactive substances (DLIS) than radioimmunoassay. SETTING: University hospital clinical research center. PARTICIPANTS: Eighteen subjects (mean age 44 yrs) with different degrees of renal function: group 1, creatinine clearance (Clcr) below 10 ml/minute; group 2, Clcr 10-50 ml/minute; and group 3, Clcr greater than 50 ml/minute (6 patients in each group). INTERVENTION: Over 5-7 days, 15 serum samples were collected after a single intravenous dose of digoxin 7 or 10 micrograms/kg actual body weight (WT) for serum concentration measurements by FPIA. Two-compartment pharmacokinetic parameters (zero-time intercept of the concentration-time curve of the initial distribution phase [A], zero-time intercept of the concentration-time curve of the terminal elimination phase [B], initial distribution phase constant [alpha], terminal elimination rate constant [beta], volume of distribution in the central compartment [Vc] and at steady state [Vss], total body clearance [Cl], mean residence time [MRT], area under the concentration-time curve [AUC]) were determined using a nonlinear least squares regression program. MEASUREMENTS AND MAIN RESULTS: No significant differences were found among groups for A, B, alpha, beta, beta-half-life Vc/WT, MRT, AUC, and Cl/WT. Significant differences were observed in Vss/WT (4.8 +/- 1.0, 6.6 +/- 0.5, 6.4 +/- 0.7 L/kg) between group 1 versus group 2 and group 1 versus group 3 (p < 0.01). Measured Clcr was correlated with Cl (r2 = 0.40, p < 0.01), Cl/WT (r2 = 0.29, p < 0.05), Vss (r2 = 0.35, p = 0.01), and Vss/WT (r2 = 0.24, p < 0.05). CONCLUSION: This study confirmed that Vss is smaller in patients with chronic renal failure (Clcr < 10 ml/min) than those without chronic renal failure. Therefore, previous recommendations that lower digoxin loading doses should be administered in patients with renal failure are applicable to digoxin serum concentration monitoring using FPIA.

Why it matters

OpenAlex reports 34 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

STUDY OBJECTIVE: To determine digoxin pharmacokinetics in subjects with different degrees of renal function using fluorescence polarization immunoassay (FPIA), which is associated with less interference from digoxin-like immunoreactive substances (DLIS) than radioimmunoassay. SETTING: University hospital clinical research center. PARTICIPANTS: Eighteen subjects (mean age 44 yrs) with different degrees of renal function: group 1, creatinine clearance (Clcr) below 10 ml/minute; group 2, Clcr 10-50 ml/minute; and group 3, Clcr greater than 50 ml/minute (6 patients in each group). INTERVENTION: Over 5-7 days, 15 serum samples were collected after a single intravenous dose of digoxin 7 or 10 micrograms/kg actual body weight (WT) for serum concentration measurements by FPIA. Two-compartment pharmacokinetic parameters (zero-time intercept of the concentration-time curve of the initial distribution phase [A], zero-time intercept of the concentration-time curve of the terminal elimination phase [B], initial distribution phase constant [alpha], terminal elimination rate constant [beta], volume of distribution in the central compartment [Vc] and at steady state [Vss], total body clearance [Cl], mean residence time [MRT], area under the concentration-time curve [AUC]) were determined using a nonlinear least squares regression program. MEASUREMENTS AND MAIN RESULTS: No significant differences were found among groups for A, B, alpha, beta, beta-half-life Vc/WT, MRT, AUC, and Cl/WT. Significant differences were observed in Vss/WT (4.8 +/- 1.0, 6.6 +/- 0.5, 6.4 +/- 0.7 L/kg) between group 1 versus group 2 and group 1 versus group 3 (p < 0.01). Measured Clcr was correlated with Cl (r2 = 0.40, p < 0.01), Cl/WT (r2 = 0.29, p < 0.05), Vss (r2 = 0.35, p = 0.01), and Vss/WT (r2 = 0.24, p < 0.05). CONCLUSION: This study confirmed that Vss is smaller in patients with chronic renal failure (Clcr < 10 ml/min) than those without chronic renal failure. Therefore, previous recommendations that lower digoxin loading doses should be administered in patients with renal failure are applicable to digoxin serum concentration monitoring using FPIA.

Key concepts: Digoxin, Pharmacokinetics, Volume of distribution, Elimination rate constant, Renal function, Fluorescence polarization immunoassay, Radioimmunoassay, Medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Is the Volume of Distribution of Digoxin Reduced in Patients with Renal Dysfunction? Determining Digoxin Pharmacokinetics by Fluorescence Polarization Immunoassay — Research Paper | ScholarLens