2011•Biomedical ChromatographyRequires access

A simple RP‐HPLC method for the simultaneous determination of curcumin and its prodrug, curcumin didecanoate, in rat plasma and the application to pharmacokinetic study

Ying-Rui Han, Jinjin Zhu, Yurong Wang, Xing-Sheng Wang, Yonghong Liao

Open publisher page 23 citations

Abstract

A high-performance liquid chromatographic (HPLC) method has been developed for the simultaneous determination of curcumin and its prodrug, curcumin didecanoate (CurDD), in rat plasma. The analytes were extracted by ethyl acetate following the addition of sodium dodecyl sulfate, and separated on a reverse-phase C(18) column using a gradient mobile phase system of acetonitrile-tetrahydrofuran-water containing 0.1% formic acid. Detection by UV absorption at 425 nm gave a lower limit of quantitation (LLOQ) of 5 and 10 ng/mL for curcumin and CurDD in 50 μL of plasma, respectively. Intra- and inter-day precisions of quality control samples except those at LLOQ were within 15% for curcumin and CurDD, respectively, and the accuracies for both compounds were between 93.9 and 108%. The method was successfully applied to determine plasma concentration-time curves of curcumin and CurDD in rats following intravenous (i.v.) administration of curcumin or CurDD at doses of 1 mg/kg (calculated as curcumin). The results suggested that i.v. dosed CurDD provided sustained plasma levels of curcumin.

About this research paper

What this paper is about

A high-performance liquid chromatographic (HPLC) method has been developed for the simultaneous determination of curcumin and its prodrug, curcumin didecanoate (CurDD), in rat plasma. The analytes were extracted by ethyl acetate following the addition of sodium dodecyl sulfate, and separated on a reverse-phase C(18) column using a gradient mobile phase system of acetonitrile-tetrahydrofuran-water containing 0.1% formic acid. Detection by UV absorption at 425 nm gave a lower limit of quantitation (LLOQ) of 5 and 10 ng/mL for curcumin and CurDD in 50 μL of plasma, respectively. Intra- and inter-day precisions of quality control samples except those at LLOQ were within 15% for curcumin and CurDD, respectively, and the accuracies for both compounds were between 93.9 and 108%. The method was successfully applied to determine plasma concentration-time curves of curcumin and CurDD in rats following intravenous (i.v.) administration of curcumin or CurDD at doses of 1 mg/kg (calculated as curcumin). The results suggested that i.v. dosed CurDD provided sustained plasma levels of curcumin.

Why it matters

OpenAlex reports 23 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A high-performance liquid chromatographic (HPLC) method has been developed for the simultaneous determination of curcumin and its prodrug, curcumin didecanoate (CurDD), in rat plasma. The analytes were extracted by ethyl acetate following the addition of sodium dodecyl sulfate, and separated on a reverse-phase C(18) column using a gradient mobile phase system of acetonitrile-tetrahydrofuran-water containing 0.1% formic acid. Detection by UV absorption at 425 nm gave a lower limit of quantitation (LLOQ) of 5 and 10 ng/mL for curcumin and CurDD in 50 μL of plasma, respectively. Intra- and inter-day precisions of quality control samples except those at LLOQ were within 15% for curcumin and CurDD, respectively, and the accuracies for both compounds were between 93.9 and 108%. The method was successfully applied to determine plasma concentration-time curves of curcumin and CurDD in rats following intravenous (i.v.) administration of curcumin or CurDD at doses of 1 mg/kg (calculated as curcumin). The results suggested that i.v. dosed CurDD provided sustained plasma levels of curcumin.

Key concepts: Chemistry, Curcumin, Chromatography, Formic acid, High-performance liquid chromatography, Pharmacokinetics, Ethyl acetate, Prodrug

Related papers

Back to paper searchBrowse research topicsOriginal source
A simple RP‐HPLC method for the simultaneous determination of curcumin and its prodrug, curcumin didecanoate, in rat plasma and the application to pharmacokinetic study — Research Paper | ScholarLens