1984•University of North Texas Digital Library (University of North Texas)Open access

Simulation of LOFT anticipated-transient experiments L6-1, L6-2, and L6-3 using TRAC-PF1/MOD1

Manjit S. Sahota

Open full text 0 citations

Abstract

Anticipated-transient experiments L6-1, L6-2, and L6-3, performed at the Loss-of-fluid Test (LOFT) facility, are analyzed using the latest released version of the Transient Reactor Analysis Code (TRAC-PF1/MOD1). The results are used to assess TRAC-PF1/MOD1 trip and control capabilities, and predictions of thermal-hydraulic phenomena during slow transients. Test L6-1 simulated a loss-of-stream load in a large pressurized-water reactor (PWR), and was initiated by closing the main steam-flow control valve (MSFCV) at its maximum rate, which reduced the heat removal from the secondary-coolant system and increased the primary-coolant system pressure that initiated a reactor scram. Test L6-2 simulated a loss-of-primary coolant flow in a large PWR, and was initiated by tripping the power to the primary-coolant pumps (PCPs) allowing the pumps to coast down. The reduced primary-coolant flow caused a reactor scram. Test L6-3 simulated an excessive-load increase incident in a large PWR, and was initiated by opening the MSFCV at its maximum rate, which increased the heat removal from the secondary-coolant system and decreased the primary-coolant system pressure that initiated a reactor scram. The TRAC calculations accurately predict most test events. The test data and the calculated results for most parameters of interest also agree well.

Open-access reader

About this research paper

What this paper is about

Anticipated-transient experiments L6-1, L6-2, and L6-3, performed at the Loss-of-fluid Test (LOFT) facility, are analyzed using the latest released version of the Transient Reactor Analysis Code (TRAC-PF1/MOD1). The results are used to assess TRAC-PF1/MOD1 trip and control capabilities, and predictions of thermal-hydraulic phenomena during slow transients. Test L6-1 simulated a loss-of-stream load in a large pressurized-water reactor (PWR), and was initiated by closing the main steam-flow control valve (MSFCV) at its maximum rate, which reduced the heat removal from the secondary-coolant system and increased the primary-coolant system pressure that initiated a reactor scram. Test L6-2 simulated a loss-of-primary coolant flow in a large PWR, and was initiated by tripping the power to the primary-coolant pumps (PCPs) allowing the pumps to coast down. The reduced primary-coolant flow caused a reactor scram. Test L6-3 simulated an excessive-load increase incident in a large PWR, and was initiated by opening the MSFCV at its maximum rate, which increased the heat removal from the secondary-coolant system and decreased the primary-coolant system pressure that initiated a reactor scram. The TRAC calculations accurately predict most test events. The test data and the calculated results for most parameters of interest also agree well.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Anticipated-transient experiments L6-1, L6-2, and L6-3, performed at the Loss-of-fluid Test (LOFT) facility, are analyzed using the latest released version of the Transient Reactor Analysis Code (TRAC-PF1/MOD1). The results are used to assess TRAC-PF1/MOD1 trip and control capabilities, and predictions of thermal-hydraulic phenomena during slow transients. Test L6-1 simulated a loss-of-stream load in a large pressurized-water reactor (PWR), and was initiated by closing the main steam-flow control valve (MSFCV) at its maximum rate, which reduced the heat removal from the secondary-coolant system and increased the primary-coolant system pressure that initiated a reactor scram. Test L6-2 simulated a loss-of-primary coolant flow in a large PWR, and was initiated by tripping the power to the primary-coolant pumps (PCPs) allowing the pumps to coast down. The reduced primary-coolant flow caused a reactor scram. Test L6-3 simulated an excessive-load increase incident in a large PWR, and was initiated by opening the MSFCV at its maximum rate, which increased the heat removal from the secondary-coolant system and decreased the primary-coolant system pressure that initiated a reactor scram. The TRAC calculations accurately predict most test events. The test data and the calculated results for most parameters of interest also agree well.

Key concepts: Scram, TRAC, Coolant, Nuclear engineering, Pressurizer, Transient (computer programming), Thermal hydraulics, Pressurized water reactor

Related papers

Back to paper searchBrowse research topicsOriginal source
Simulation of LOFT anticipated-transient experiments L6-1, L6-2, and L6-3 using TRAC-PF1/MOD1 — Research Paper | ScholarLens