2001Netherlands Journal of Geosciences – Geologie en MijnbouwOpen access

Laser-diffraction and pipette-method grain sizing of Dutch sediments: correlations for fine fractions of marine, fluvial, and loess samples

P. Buurman, Th. Pape, J.A. Reijneveld, Frank de Jong, E. van Gelder

Open full text 127 citations

Abstract

Abstract To evaluate correlations between silt and clay fractions determined by pipette method and laser diffraction, samples from Dutch fine marine, fluvial, and loess deposits were analysed by both methods. For fluvial deposits, correlations for fractions <2 and >50 μm were excellent (R2 > 0.95), those for 2–4, 4–8, 16–32 and 32–50 μm were satisfactory (R2 = 0.80 – 0.95), while that for the fraction 8–16 μm had an R2 of only 0.68. For marine deposits, correlations for <2 and >50 μm were in the same range, but those of all other fractions except 8–16 μm were lower. In the loess samples, correlations for all but the 8–16 μm fraction were unsatisfactory. Laser diffraction gave 42% of pipette clay in marine samples, and 62% in fluvial and loess samples if regressions are forced through 0. Sand fractions detected by laser diffraction were 107% of the sieve fraction in marine samples, and 99% in the fluvial samples. Correlations for fractions smaller than reference size are generally better than those for individual size fractions. Both the 2 μm and the 50 μm boundary cause problems in the comparison. The first because of platy shape of clay minerals, and the second due to both a change in method in the pipette/sieving procedure, and to non-sphericity of particles. Apparently, correlations for clay- and silt-size fractions obtained by pipette method and laser diffraction will be different for each type of sediment.

Open-access reader

About this research paper

What this paper is about

Abstract To evaluate correlations between silt and clay fractions determined by pipette method and laser diffraction, samples from Dutch fine marine, fluvial, and loess deposits were analysed by both methods. For fluvial deposits, correlations for fractions <2 and >50 μm were excellent (R2 > 0.95), those for 2–4, 4–8, 16–32 and 32–50 μm were satisfactory (R2 = 0.80 – 0.95), while that for the fraction 8–16 μm had an R2 of only 0.68. For marine deposits, correlations for <2 and >50 μm were in the same range, but those of all other fractions except 8–16 μm were lower. In the loess samples, correlations for all but the 8–16 μm fraction were unsatisfactory. Laser diffraction gave 42% of pipette clay in marine samples, and 62% in fluvial and loess samples if regressions are forced through 0. Sand fractions detected by laser diffraction were 107% of the sieve fraction in marine samples, and 99% in the fluvial samples. Correlations for fractions smaller than reference size are generally better than those for individual size fractions. Both the 2 μm and the 50 μm boundary cause problems in the comparison. The first because of platy shape of clay minerals, and the second due to both a change in method in the pipette/sieving procedure, and to non-sphericity of particles. Apparently, correlations for clay- and silt-size fractions obtained by pipette method and laser diffraction will be different for each type of sediment.

Why it matters

OpenAlex reports 127 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract To evaluate correlations between silt and clay fractions determined by pipette method and laser diffraction, samples from Dutch fine marine, fluvial, and loess deposits were analysed by both methods. For fluvial deposits, correlations for fractions <2 and >50 μm were excellent (R2 > 0.95), those for 2–4, 4–8, 16–32 and 32–50 μm were satisfactory (R2 = 0.80 – 0.95), while that for the fraction 8–16 μm had an R2 of only 0.68. For marine deposits, correlations for <2 and >50 μm were in the same range, but those of all other fractions except 8–16 μm were lower. In the loess samples, correlations for all but the 8–16 μm fraction were unsatisfactory. Laser diffraction gave 42% of pipette clay in marine samples, and 62% in fluvial and loess samples if regressions are forced through 0. Sand fractions detected by laser diffraction were 107% of the sieve fraction in marine samples, and 99% in the fluvial samples. Correlations for fractions smaller than reference size are generally better than those for individual size fractions. Both the 2 μm and the 50 μm boundary cause problems in the comparison. The first because of platy shape of clay minerals, and the second due to both a change in method in the pipette/sieving procedure, and to non-sphericity of particles. Apparently, correlations for clay- and silt-size fractions obtained by pipette method and laser diffraction will be different for each type of sediment.

Key concepts: Silt, Loess, Pipette, Fluvial, Sediment, Geology, Mineralogy, Fraction (chemistry)

Related papers

Back to paper searchBrowse research topicsOriginal source
Laser-diffraction and pipette-method grain sizing of Dutch sediments: correlations for fine fractions of marine, fluvial, and loess samples — Research Paper | ScholarLens