Multi-Push (MP) ARF assessment of viscoelastic properties in a tissue mimicking phantom effect of time separation
Mallory R. Scola, Caterina M. Gallippi
Abstract
Mallory R. Scola, Caterina M. Gallippi
Abstract
We present a new approach to differentiating the viscoelastic properties of tissue, Multi-Push Acoustic Radiation Force (MP ARF) ultrasound, in which displacements achieved by successive ARF excitations are compared to qualitatively assess viscoelastic tissue parameters. We evaluate the MP ARF measures of marginal peak displacement (MPD) in four tissue-mimicking phantoms using different time separations between successive excitations. A time separation of 0.4 ms between excitations yielded the best contrast when differentiating between a phantom with low stiff, low viscosity and a phantom with high stiffness, low viscosity. Similarly, 0.4 ms between excitations gave the best MPD contrast between a phantom with low stiffness, low viscosity and a phantom with low stiffness, high viscosity. A time separation of 1.2 ms gave the optimal separation when differentiating between a phantom with high stiffness, low viscosity and a phantom with high stiffness, high viscosity. MPD was also shown to be is less depth-dependent than first peak displacement.
OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
We present a new approach to differentiating the viscoelastic properties of tissue, Multi-Push Acoustic Radiation Force (MP ARF) ultrasound, in which displacements achieved by successive ARF excitations are compared to qualitatively assess viscoelastic tissue parameters. We evaluate the MP ARF measures of marginal peak displacement (MPD) in four tissue-mimicking phantoms using different time separations between successive excitations. A time separation of 0.4 ms between excitations yielded the best contrast when differentiating between a phantom with low stiff, low viscosity and a phantom with high stiffness, low viscosity. Similarly, 0.4 ms between excitations gave the best MPD contrast between a phantom with low stiffness, low viscosity and a phantom with low stiffness, high viscosity. A time separation of 1.2 ms gave the optimal separation when differentiating between a phantom with high stiffness, low viscosity and a phantom with high stiffness, high viscosity. MPD was also shown to be is less depth-dependent than first peak displacement.
Key concepts: Imaging phantom, Viscoelasticity, Acoustic radiation force, Viscosity, Stiffness, Materials science, Displacement (psychology), Biomedical engineering