Cooling Load Temperature Differential Values For Buildings In Ghana

Felix Uba, Emmanuel A. Sarsah

Open publisher page 3 citations

Abstract

Wrong sizing of equipment is often the result of inaccurate procedures employed to estimate the cooling load of the air conditioned space. Long term weather information was used to develop cooling load temperature differential (CLTD) values made of materials commonly used in Ghana. The CLTD are produced from ASHRAE mathematical models and weather information of Accra, Ghana. The CLTD was obtained for each wall and roof type after dividing the results from the Transfer Function Method, TFM by the overall heat transfer coefficient of the envelope material. This method makes hand calculation of cooling load possible and gives satisfactory results when compared with complex cooling load tools.

About this research paper

What this paper is about

Wrong sizing of equipment is often the result of inaccurate procedures employed to estimate the cooling load of the air conditioned space. Long term weather information was used to develop cooling load temperature differential (CLTD) values made of materials commonly used in Ghana. The CLTD are produced from ASHRAE mathematical models and weather information of Accra, Ghana. The CLTD was obtained for each wall and roof type after dividing the results from the Transfer Function Method, TFM by the overall heat transfer coefficient of the envelope material. This method makes hand calculation of cooling load possible and gives satisfactory results when compared with complex cooling load tools.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Wrong sizing of equipment is often the result of inaccurate procedures employed to estimate the cooling load of the air conditioned space. Long term weather information was used to develop cooling load temperature differential (CLTD) values made of materials commonly used in Ghana. The CLTD are produced from ASHRAE mathematical models and weather information of Accra, Ghana. The CLTD was obtained for each wall and roof type after dividing the results from the Transfer Function Method, TFM by the overall heat transfer coefficient of the envelope material. This method makes hand calculation of cooling load possible and gives satisfactory results when compared with complex cooling load tools.

Key concepts: Cooling load, Sizing, ASHRAE 90.1, Envelope (radar), Roof, Differential (mechanical device), Heat load, Environmental science

Related papers

Back to paper searchBrowse research topicsOriginal source