1986Unpublished venueOpen access

Evaluation of core damage sequences initiated by loss of reactor coolant pump seal cooling

Sourav Mitra, R. Baradaran, Robert Youngblood

Open full text 0 citations

Abstract

This report is concerned with core damage accident sequences initiated by loss of component cooling water, leading to loss of reactor coolant pump seal cooling, subsequent primary coolant leakage, and failure to make up the coolant loss. Three plants are considered: Indian Point Unit 3, Midland Unit 2, and Calvert Cliffs Unit 1. It is shown that design differences in the overall seal cooling support systems are responsible for considerable variation in the likelihood of, and plant response to, loss of component cooling.

Open-access reader

About this research paper

What this paper is about

This report is concerned with core damage accident sequences initiated by loss of component cooling water, leading to loss of reactor coolant pump seal cooling, subsequent primary coolant leakage, and failure to make up the coolant loss. Three plants are considered: Indian Point Unit 3, Midland Unit 2, and Calvert Cliffs Unit 1. It is shown that design differences in the overall seal cooling support systems are responsible for considerable variation in the likelihood of, and plant response to, loss of component cooling.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This report is concerned with core damage accident sequences initiated by loss of component cooling water, leading to loss of reactor coolant pump seal cooling, subsequent primary coolant leakage, and failure to make up the coolant loss. Three plants are considered: Indian Point Unit 3, Midland Unit 2, and Calvert Cliffs Unit 1. It is shown that design differences in the overall seal cooling support systems are responsible for considerable variation in the likelihood of, and plant response to, loss of component cooling.

Key concepts: Coolant, Seal (emblem), Pressurizer, Nuclear engineering, Leakage (economics), Water cooling, Component (thermodynamics), Environmental science

Related papers

Back to paper searchBrowse research topicsOriginal source
Evaluation of core damage sequences initiated by loss of reactor coolant pump seal cooling — Research Paper | ScholarLens