Diagnostic Lines for the 160 MeV H Linac4 at CERN
B. Mikulec, G. Bellodi, Th. Hermanns, Klaus Peter Hanke, Mohammad Eshraqi
Abstract
Open-access reader
B. Mikulec, G. Bellodi, Th. Hermanns, Klaus Peter Hanke, Mohammad Eshraqi
Abstract
Open-access reader
Linac4 will be the new linear accelerator of the CERN accelerator chain delivering H- ions at 160 MeV from 2016. The increased injection energy compared to the 50 MeV of its predecessor Linac2, combined with a H- charge-exchange injection, will pave the way to reach ultimate goals for the LHC luminosity. Extensive commissioning of Linac4 is planned for the coming years. For this purpose, the beam will be studied after the exit of Linac4 in a straight line ending at the Linac4 dump, equipped with various beam instruments. An almost 180 m long transfer line will guide the beam to the charge-exchange injection point at the entry of the Proton Synchrotron Booster (PSB). About 50 m upstream of this point, two measurement lines will be upgraded to perform transverse emittance measurements as well as energy and energy spread measurements of the Linac4 beam. A detailed description of the beam measurement principles and setups at these three Linac4 diagnostics lines related to distinct Linac4 commissioning phases will be given.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Linac4 will be the new linear accelerator of the CERN accelerator chain delivering H- ions at 160 MeV from 2016. The increased injection energy compared to the 50 MeV of its predecessor Linac2, combined with a H- charge-exchange injection, will pave the way to reach ultimate goals for the LHC luminosity. Extensive commissioning of Linac4 is planned for the coming years. For this purpose, the beam will be studied after the exit of Linac4 in a straight line ending at the Linac4 dump, equipped with various beam instruments. An almost 180 m long transfer line will guide the beam to the charge-exchange injection point at the entry of the Proton Synchrotron Booster (PSB). About 50 m upstream of this point, two measurement lines will be upgraded to perform transverse emittance measurements as well as energy and energy spread measurements of the Linac4 beam. A detailed description of the beam measurement principles and setups at these three Linac4 diagnostics lines related to distinct Linac4 commissioning phases will be given.
Key concepts: Large Hadron Collider, Thermal emittance, Physics, Beam (structure), Beamline, Transfer line, Linear particle accelerator, Nuclear physics