New effective dose estimates for Rubidium-82 based on dynamic PET/CT imaging in humans
Chad Hunter, María Cecilia Ziadi, Judy Etele, Jeremy Hill, Robert Beanlands, Robert A. deKemp
Abstract
Chad Hunter, María Cecilia Ziadi, Judy Etele, Jeremy Hill, Robert Beanlands, Robert A. deKemp
Abstract
1429 Objectives Published radiation dose estimates for Rubidium-82 vary widely, and no comprehensive study in man has yet been conducted. With the increasing use of Rb-82 PET for myocardial perfusion imaging, improved dosimetry information is needed for accurate risk assessment. The purpose of this study was to measure Rb-82 internal organ and effective doses with PET/CT in humans. Methods We recruited 26 cardiac patients and 4 normal subjects with no cardiac history. Dynamic 3D PET scans were acquired (GE Discovery RX/VCT) over 10 minutes following IV injection of 10 MBq/kg Rb-82. Images were reconstructed using FORE-OSEM and 8 mm Hann filter. Cardiac scans of the chest were acquired at rest for all 30 subjects, plus one additional scan of the Head, Neck, Abdomen, Pelvis, or Thighs. Mean Rb-82 residence times were determined in 22 source organs using volumes-of-interest (VOI) drawn on the fused PET/CT images. For large organs a small VOI was used to avoid partial volume losses. For small organs the average activity above 80% threshold was multiplied by the volume at 40% of the peak value within the organ VOI. Target organ doses and the effective dose estimate were calculated using OLINDA/EXM 1.0 according to ICRP 60, and recalculated according to ICRP 103. Results A total of 283 organs were measured across the 60 scans, with at least 4 samples obtained in each source organ. The average ‘adult’ effective dose for Rubidium-82 was found to be 0.00074 mSv/MBq using ICRP 60. Using ICRP 103, the male and female effective doses were 0.00074 and 0.00092 mSv/MBq respectively. The highest absorbed organ dose was to the kidneys. Conclusions These dose estimates for Rubidium-82 are the first to be measured directly with PET/CT in humans, and are 4 to 4.5 times lower than previous ICRP 60 values based on a theoretical blood flow model. The new values derived from human studies suggest a typical effective dose of 0.6 mSv per scan with 3D PET. Research Support DRAXimage, Ontario Research Fund
OpenAlex reports 12 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
1429 Objectives Published radiation dose estimates for Rubidium-82 vary widely, and no comprehensive study in man has yet been conducted. With the increasing use of Rb-82 PET for myocardial perfusion imaging, improved dosimetry information is needed for accurate risk assessment. The purpose of this study was to measure Rb-82 internal organ and effective doses with PET/CT in humans. Methods We recruited 26 cardiac patients and 4 normal subjects with no cardiac history. Dynamic 3D PET scans were acquired (GE Discovery RX/VCT) over 10 minutes following IV injection of 10 MBq/kg Rb-82. Images were reconstructed using FORE-OSEM and 8 mm Hann filter. Cardiac scans of the chest were acquired at rest for all 30 subjects, plus one additional scan of the Head, Neck, Abdomen, Pelvis, or Thighs. Mean Rb-82 residence times were determined in 22 source organs using volumes-of-interest (VOI) drawn on the fused PET/CT images. For large organs a small VOI was used to avoid partial volume losses. For small organs the average activity above 80% threshold was multiplied by the volume at 40% of the peak value within the organ VOI. Target organ doses and the effective dose estimate were calculated using OLINDA/EXM 1.0 according to ICRP 60, and recalculated according to ICRP 103. Results A total of 283 organs were measured across the 60 scans, with at least 4 samples obtained in each source organ. The average ‘adult’ effective dose for Rubidium-82 was found to be 0.00074 mSv/MBq using ICRP 60. Using ICRP 103, the male and female effective doses were 0.00074 and 0.00092 mSv/MBq respectively. The highest absorbed organ dose was to the kidneys. Conclusions These dose estimates for Rubidium-82 are the first to be measured directly with PET/CT in humans, and are 4 to 4.5 times lower than previous ICRP 60 values based on a theoretical blood flow model. The new values derived from human studies suggest a typical effective dose of 0.6 mSv per scan with 3D PET. Research Support DRAXimage, Ontario Research Fund
Key concepts: Nuclear medicine, Medicine, Effective dose (radiation), Dosimetry, Abdomen, Partial volume, Myocardial perfusion imaging, Head and neck