1996Fusion TechnologyRequires access

Removal of Tritium from TFTR

D. Mueller, W. Blanchard, J. Collins, J. Hosea, J. Kamperschroer, A. Nagy, D.K. Owens, S. Raftopoulos, C.H. Skinner

Open publisher page 7 citations

Abstract

Operation of the Tokamak Fusion Test Reactor (TFTR) with a mixture of deuterium and tritium fueling has permitted the opportunity to measure the retention of tritium in the graphite limiter and other internal hardware. The use of discharge cleaning techniques and venting to remove the tritium was investigated. The tritium was introduced into TFTR by neutral beam injection and by gas puffing. The graphite limiter is subject to erosion and codeposition. While short term retention was high, the retention averaged over the 1993-1995 D-T campaign was 52 % +/- 15 %. The tritium removal techniques resulted in lowering the in-vessel inventory from 16.4 kCi at the end of 1995 operation to 7.2 kCi at the start of the 1996 experimental program.

About this research paper

What this paper is about

Operation of the Tokamak Fusion Test Reactor (TFTR) with a mixture of deuterium and tritium fueling has permitted the opportunity to measure the retention of tritium in the graphite limiter and other internal hardware. The use of discharge cleaning techniques and venting to remove the tritium was investigated. The tritium was introduced into TFTR by neutral beam injection and by gas puffing. The graphite limiter is subject to erosion and codeposition. While short term retention was high, the retention averaged over the 1993-1995 D-T campaign was 52 % +/- 15 %. The tritium removal techniques resulted in lowering the in-vessel inventory from 16.4 kCi at the end of 1995 operation to 7.2 kCi at the start of the 1996 experimental program.

Why it matters

OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Operation of the Tokamak Fusion Test Reactor (TFTR) with a mixture of deuterium and tritium fueling has permitted the opportunity to measure the retention of tritium in the graphite limiter and other internal hardware. The use of discharge cleaning techniques and venting to remove the tritium was investigated. The tritium was introduced into TFTR by neutral beam injection and by gas puffing. The graphite limiter is subject to erosion and codeposition. While short term retention was high, the retention averaged over the 1993-1995 D-T campaign was 52 % +/- 15 %. The tritium removal techniques resulted in lowering the in-vessel inventory from 16.4 kCi at the end of 1995 operation to 7.2 kCi at the start of the 1996 experimental program.

Key concepts: Tritium, Tokamak Fusion Test Reactor, Limiter, Nuclear engineering, Deuterium, Tokamak, Materials science, Graphite

Related papers

Back to paper searchBrowse research topicsOriginal source
Removal of Tritium from TFTR — Research Paper | ScholarLens