2014Journal of Architectural/Planning Research and Studies (JARS)Open access

Design Guideline of Office Building Facade with Self-Shading for Energy Conservation in Hot-Humid Climate

Ratha Jittawisutthikul, Jatuwat Varodompun

Open full text 4 citations

Abstract

AbstractThis research aims at studying the solution for reducing energy consumption of an office building facade with self-shading applications. The four important design variables include orientations, extension self-shading length, Window to Wall Ratio (WWR) and automatic daylight dimmer. Using the simulation program called eQUEST-3.64. This study focuses on self-shading of facade with both single and multiple orientations with 4 variables including shading length, orientations, daylight dimmer, and applications comparison. For the shading length, the research results show that length of a self-shading facade affected the energy reduction most. Self-shading of 2.5 m can achieve the highest energy saving of wide WWR range from 20% - 100%. Also, the most feasible orientation of the self-shading facade is the east, while the north is not suitable for self-shading application. For the daylight dimmer, it can reduce the energy consumption by up to 12% when WWR is optimized. When comparing the self-shading with other applications including shading device and tilted wall, it is found that the self-shading at WWR 20% - 80% is the most efficient solution. Moreover, the energy saving extends greater if using self-shading facade is applied for multiple orientations. The results from this research are useful for architects who are interested in the facade design, and can effectively use self-shading facade to maximize energy conservation benefit.

About this research paper

What this paper is about

AbstractThis research aims at studying the solution for reducing energy consumption of an office building facade with self-shading applications. The four important design variables include orientations, extension self-shading length, Window to Wall Ratio (WWR) and automatic daylight dimmer. Using the simulation program called eQUEST-3.64. This study focuses on self-shading of facade with both single and multiple orientations with 4 variables including shading length, orientations, daylight dimmer, and applications comparison. For the shading length, the research results show that length of a self-shading facade affected the energy reduction most. Self-shading of 2.5 m can achieve the highest energy saving of wide WWR range from 20% - 100%. Also, the most feasible orientation of the self-shading facade is the east, while the north is not suitable for self-shading application. For the daylight dimmer, it can reduce the energy consumption by up to 12% when WWR is optimized. When comparing the self-shading with other applications including shading device and tilted wall, it is found that the self-shading at WWR 20% - 80% is the most efficient solution. Moreover, the energy saving extends greater if using self-shading facade is applied for multiple orientations. The results from this research are useful for architects who are interested in the facade design, and can effectively use self-shading facade to maximize energy conservation benefit.

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

AbstractThis research aims at studying the solution for reducing energy consumption of an office building facade with self-shading applications. The four important design variables include orientations, extension self-shading length, Window to Wall Ratio (WWR) and automatic daylight dimmer. Using the simulation program called eQUEST-3.64. This study focuses on self-shading of facade with both single and multiple orientations with 4 variables including shading length, orientations, daylight dimmer, and applications comparison. For the shading length, the research results show that length of a self-shading facade affected the energy reduction most. Self-shading of 2.5 m can achieve the highest energy saving of wide WWR range from 20% - 100%. Also, the most feasible orientation of the self-shading facade is the east, while the north is not suitable for self-shading application. For the daylight dimmer, it can reduce the energy consumption by up to 12% when WWR is optimized. When comparing the self-shading with other applications including shading device and tilted wall, it is found that the self-shading at WWR 20% - 80% is the most efficient solution. Moreover, the energy saving extends greater if using self-shading facade is applied for multiple orientations. The results from this research are useful for architects who are interested in the facade design, and can effectively use self-shading facade to maximize energy conservation benefit.

Key concepts: Shading, Facade, Daylight, Dimmer, Energy consumption, Computer science, Architectural engineering, Environmental science

Related papers

Back to paper searchBrowse research topicsOriginal source
Design Guideline of Office Building Facade with Self-Shading for Energy Conservation in Hot-Humid Climate — Research Paper | ScholarLens