Talon zips to $200,000 energy savings. [Reduced energy use by 12%]
Michael L Millenson
Abstract
Michael L Millenson
Abstract
A 12 percent reduction in energy consumption saved Talon $200,000 last year, while another 9.5 percent planned for the present year will exhaust low-capital housekeeping measures. Further energy savings will require capital expenditures for monitoring and engineering equipment, such as timing devices to reduce peak loads. Talon's conservation program centers on a formal system of plant energy managers and committees to set goals and policies and then report to the energy management coordinator. Fuel prices and availability are monitored continuously to determine when alternative fuels should be used. Other techniques avoid electric power demand at peak periods, insulate windows and eliminate northern exposure windows, and replace conventional warehouse lights with high-pressure sodium and mercury vapor lights. A request for ERDA funds to test solar water heating in Talon's dye house was not approved. (DCK)
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A 12 percent reduction in energy consumption saved Talon $200,000 last year, while another 9.5 percent planned for the present year will exhaust low-capital housekeeping measures. Further energy savings will require capital expenditures for monitoring and engineering equipment, such as timing devices to reduce peak loads. Talon's conservation program centers on a formal system of plant energy managers and committees to set goals and policies and then report to the energy management coordinator. Fuel prices and availability are monitored continuously to determine when alternative fuels should be used. Other techniques avoid electric power demand at peak periods, insulate windows and eliminate northern exposure windows, and replace conventional warehouse lights with high-pressure sodium and mercury vapor lights. A request for ERDA funds to test solar water heating in Talon's dye house was not approved. (DCK)
Key concepts: Energy conservation, Capital expenditure, Capital cost, Environmental science, Housekeeping, Operations management, Business, Environmental economics