2001ASHRAE journalRequires access

Improving the Efficiency of Chilled Water Plants

G. Avery

Open publisher page 38 citations

Abstract

For the past 30 or more years most central chilled water plants have used primary-secondary pumping arrangements as shown in Figure 1. The primary system includes all equipment to the plant side of Points A and B and the secondary system includes all equipment to the load side of these points. The majority of these systems have the chillers staged from flow. As the flow in the secondary starts to exceed the flow in the primary, an additional primary pump and chiller is staged on. As the flow in the secondary decreases, so that one less chiller can handle the reduced flow, a pump and chiller is staged off. This method of control assumes that the load is proportional to flow and that the ΔT between the chilled water supply and return is constant and at the design condition.

About this research paper

What this paper is about

For the past 30 or more years most central chilled water plants have used primary-secondary pumping arrangements as shown in Figure 1. The primary system includes all equipment to the plant side of Points A and B and the secondary system includes all equipment to the load side of these points. The majority of these systems have the chillers staged from flow. As the flow in the secondary starts to exceed the flow in the primary, an additional primary pump and chiller is staged on. As the flow in the secondary decreases, so that one less chiller can handle the reduced flow, a pump and chiller is staged off. This method of control assumes that the load is proportional to flow and that the ΔT between the chilled water supply and return is constant and at the design condition.

Why it matters

OpenAlex reports 38 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

For the past 30 or more years most central chilled water plants have used primary-secondary pumping arrangements as shown in Figure 1. The primary system includes all equipment to the plant side of Points A and B and the secondary system includes all equipment to the load side of these points. The majority of these systems have the chillers staged from flow. As the flow in the secondary starts to exceed the flow in the primary, an additional primary pump and chiller is staged on. As the flow in the secondary decreases, so that one less chiller can handle the reduced flow, a pump and chiller is staged off. This method of control assumes that the load is proportional to flow and that the ΔT between the chilled water supply and return is constant and at the design condition.

Key concepts: Chilled water, Chiller, Water chiller, Flow (mathematics), Environmental science, Engineering, Process engineering, Waste management

Related papers

Back to paper searchBrowse research topicsOriginal source
Improving the Efficiency of Chilled Water Plants — Research Paper | ScholarLens