Abstract

Standard protein quantitation is an involved process, often including serial dilution of standards and plotting of sample values on a curve of values obtained from the dilution series. Through integration of fluorescent reagents and a low cost fluorescent instrument programmed with a curve fitting algorithm, we have developed a fast and accurate method of protein quantitation that eliminates both calibration standard preparation and manual calculation. In the Quant‐iT Protein Assay for the Qubit® fluorometer, a fluorescent reagent is mixed with a dilution buffer, and the mixture is added to only three premixed calibration standards and to all samples. Instrument readings of the three standards are automatically fit to a sigmoidal curve, allowing concentration of the sample in μg/mL to be the only output. The assay is accurate for initial sample concentrations from 12.5 μg/mL to 5 mg/mL and exhibits low protein‐to‐protein variation. The assay is performed at room temperature, and the signal is stable for three hours. Common contaminants, such as reducing agents, salts, free nucleotides, amino acids, solvents, and DNA or RNA, but not detergents, are well tolerated in the assay. Samples in standard protein 1D, but not 2D, gel loading buffer may be diluted and then quantitated in the assay. The entire assay takes about 20 minutes to perform.

About this research paper

What this paper is about

Standard protein quantitation is an involved process, often including serial dilution of standards and plotting of sample values on a curve of values obtained from the dilution series. Through integration of fluorescent reagents and a low cost fluorescent instrument programmed with a curve fitting algorithm, we have developed a fast and accurate method of protein quantitation that eliminates both calibration standard preparation and manual calculation. In the Quant‐iT Protein Assay for the Qubit® fluorometer, a fluorescent reagent is mixed with a dilution buffer, and the mixture is added to only three premixed calibration standards and to all samples. Instrument readings of the three standards are automatically fit to a sigmoidal curve, allowing concentration of the sample in μg/mL to be the only output. The assay is accurate for initial sample concentrations from 12.5 μg/mL to 5 mg/mL and exhibits low protein‐to‐protein variation. The assay is performed at room temperature, and the signal is stable for three hours. Common contaminants, such as reducing agents, salts, free nucleotides, amino acids, solvents, and DNA or RNA, but not detergents, are well tolerated in the assay. Samples in standard protein 1D, but not 2D, gel loading buffer may be diluted and then quantitated in the assay. The entire assay takes about 20 minutes to perform.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Standard protein quantitation is an involved process, often including serial dilution of standards and plotting of sample values on a curve of values obtained from the dilution series. Through integration of fluorescent reagents and a low cost fluorescent instrument programmed with a curve fitting algorithm, we have developed a fast and accurate method of protein quantitation that eliminates both calibration standard preparation and manual calculation. In the Quant‐iT Protein Assay for the Qubit® fluorometer, a fluorescent reagent is mixed with a dilution buffer, and the mixture is added to only three premixed calibration standards and to all samples. Instrument readings of the three standards are automatically fit to a sigmoidal curve, allowing concentration of the sample in μg/mL to be the only output. The assay is accurate for initial sample concentrations from 12.5 μg/mL to 5 mg/mL and exhibits low protein‐to‐protein variation. The assay is performed at room temperature, and the signal is stable for three hours. Common contaminants, such as reducing agents, salts, free nucleotides, amino acids, solvents, and DNA or RNA, but not detergents, are well tolerated in the assay. Samples in standard protein 1D, but not 2D, gel loading buffer may be diluted and then quantitated in the assay. The entire assay takes about 20 minutes to perform.

Key concepts: Fluorometer, Dilution, Calibration curve, Standard curve, Chromatography, Reagent, Chemistry, Standard solution