1993•Water Science & TechnologyRequires access

A 5 pH Point Titration Method for Determining the Carbonate and SCFA Weak Acid/Bases in Anaerobic Systems

R. E. Moosbrugger, M. C. Wentzel, George A. Ekama, G. v. R. Marais

Open publisher page 77 citations

Abstract

A 5 pH point acid titration method is proposed to measure the short chain fatty acids, total carbonate species concentration and H2CO3*alkalinity in anaerobic systems. To test the method, aqueous solutions containing NaHCO3 (1990; 2488 mg/ℓ as CaCO3) and the short chain fatty acid (SCFA) acetic acid with concentrations ranging from 100 to 1000 mg/ℓ were titrated using the method; the H2CO3*alkalinity and SCFA estimates ranged around the expected values with an average standard deviation of 5 and 8 percent respectively. Estimates of the SCFA by the method and by Montgomery et al 's wet chemical method on the effluents of UASB reactors treating brewery and wine distillery waste correlated closely (r = 0.98). Other tests demonstrated as predicted that the presence of ammonium has a negligible effect on the derived results. However, phosphates can have a significant effect on the H2CO3*alkalinity but not on the SCFA estimates. The phosphate effect is eliminated in the derived estimates if its concentration is known. The method also identifies errors in pH due to the residual liquid junction effect or poor calibration and corrects the estimates accordingly; deliberately imposed pH calibration errors were identified and their error effects on the H2CO3*alkalinity and SCFA estimates largely corrected.

About this research paper

What this paper is about

A 5 pH point acid titration method is proposed to measure the short chain fatty acids, total carbonate species concentration and H2CO3*alkalinity in anaerobic systems. To test the method, aqueous solutions containing NaHCO3 (1990; 2488 mg/ℓ as CaCO3) and the short chain fatty acid (SCFA) acetic acid with concentrations ranging from 100 to 1000 mg/ℓ were titrated using the method; the H2CO3*alkalinity and SCFA estimates ranged around the expected values with an average standard deviation of 5 and 8 percent respectively. Estimates of the SCFA by the method and by Montgomery et al 's wet chemical method on the effluents of UASB reactors treating brewery and wine distillery waste correlated closely (r = 0.98). Other tests demonstrated as predicted that the presence of ammonium has a negligible effect on the derived results. However, phosphates can have a significant effect on the H2CO3*alkalinity but not on the SCFA estimates. The phosphate effect is eliminated in the derived estimates if its concentration is known. The method also identifies errors in pH due to the residual liquid junction effect or poor calibration and corrects the estimates accordingly; deliberately imposed pH calibration errors were identified and their error effects on the H2CO3*alkalinity and SCFA estimates largely corrected.

Why it matters

OpenAlex reports 77 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A 5 pH point acid titration method is proposed to measure the short chain fatty acids, total carbonate species concentration and H2CO3*alkalinity in anaerobic systems. To test the method, aqueous solutions containing NaHCO3 (1990; 2488 mg/ℓ as CaCO3) and the short chain fatty acid (SCFA) acetic acid with concentrations ranging from 100 to 1000 mg/ℓ were titrated using the method; the H2CO3*alkalinity and SCFA estimates ranged around the expected values with an average standard deviation of 5 and 8 percent respectively. Estimates of the SCFA by the method and by Montgomery et al 's wet chemical method on the effluents of UASB reactors treating brewery and wine distillery waste correlated closely (r = 0.98). Other tests demonstrated as predicted that the presence of ammonium has a negligible effect on the derived results. However, phosphates can have a significant effect on the H2CO3*alkalinity but not on the SCFA estimates. The phosphate effect is eliminated in the derived estimates if its concentration is known. The method also identifies errors in pH due to the residual liquid junction effect or poor calibration and corrects the estimates accordingly; deliberately imposed pH calibration errors were identified and their error effects on the H2CO3*alkalinity and SCFA estimates largely corrected.

Key concepts: Alkalinity, Titration, Chemistry, Acid–base titration, Carbonate, Ammonium, Effluent, Anaerobic exercise

Related papers

Back to paper searchBrowse research topicsOriginal source
A 5 pH Point Titration Method for Determining the Carbonate and SCFA Weak Acid/Bases in Anaerobic Systems — Research Paper | ScholarLens