1971•Unpublished venueRequires access

Light Element Analysis Using the Semiconductor X-ray Energy Spectrometer with Electron Excitation

JC Russ

Open publisher page 1 citations

Abstract

Limitations on light element analysis include the low fluorescent yield of low atomic number elements and the interference of closely spaced K-lines and the L- and M-lines of heavier elements. The paper discusses the relative contributions of electronic noise and statistical line width for low-energy X-rays and the effect of detector window thickness, along with the possibility of reducing or eliminating the window. Optimum accelerating voltages for light elements are calculated, and the importance of takeoff angle is stressed. Examples are given of the minimum detectable limits obtainable at the present state of the art; the possibilities for development in the near future are discussed.

About this research paper

What this paper is about

Limitations on light element analysis include the low fluorescent yield of low atomic number elements and the interference of closely spaced K-lines and the L- and M-lines of heavier elements. The paper discusses the relative contributions of electronic noise and statistical line width for low-energy X-rays and the effect of detector window thickness, along with the possibility of reducing or eliminating the window. Optimum accelerating voltages for light elements are calculated, and the importance of takeoff angle is stressed. Examples are given of the minimum detectable limits obtainable at the present state of the art; the possibilities for development in the near future are discussed.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Limitations on light element analysis include the low fluorescent yield of low atomic number elements and the interference of closely spaced K-lines and the L- and M-lines of heavier elements. The paper discusses the relative contributions of electronic noise and statistical line width for low-energy X-rays and the effect of detector window thickness, along with the possibility of reducing or eliminating the window. Optimum accelerating voltages for light elements are calculated, and the importance of takeoff angle is stressed. Examples are given of the minimum detectable limits obtainable at the present state of the art; the possibilities for development in the near future are discussed.

Key concepts: Spectrometer, Semiconductor, Electron, Excitation, Optics, Line (geometry), Detector, Atomic physics

Related papers

Back to paper searchBrowse research topicsOriginal source
Light Element Analysis Using the Semiconductor X-ray Energy Spectrometer with Electron Excitation — Research Paper | ScholarLens