1996TURKISH JOURNAL OF MEDICAL SCIENCESRequires access

Elemental Analysis of Serum by Inductively Coupled Plasma Atomic Emission Spectroscopy in Comparison to Atomic Absorption Spectroscopy

Canan Çöker, Biltan Ersöz, Sara Habif, Nurten ÇETİNER, Yılmaz GÜLTEKİN

Open publisher page 5 citations

Abstract

Inductively Coupled Plasma Atomic Emission Spectroscopy (ICP-AES), a modern technique with high sensitivity, accuracy and low matrix effect, is applied extensively in multielement analysis of serum and other biological materials. The objective of this study has been to develop a reliable and practical method for ICP-AES to estimate the serum concentrations of Zn, Cu, Fe, Mg, Ca, Na and K. 60 serum specimens were analyzed by both ICP-AES and Atomic Absorption Spectroscopy (AAS). The results were compared by the t-test and linear regression analysis. In comparison to the AAS method, the ICP-AES yields slightly higher Cu, Mg, Ca and K, and lower Zn, Fe and Na values. Except for Zn (r= 0.612), the correlation between the results is very high (³0.942), indicating that the ICP-AES results are equally satisfactory. In conclusion, ICP-AES is a reliable technique with the advantages of minimal sample volume and analysis time.

About this research paper

What this paper is about

Inductively Coupled Plasma Atomic Emission Spectroscopy (ICP-AES), a modern technique with high sensitivity, accuracy and low matrix effect, is applied extensively in multielement analysis of serum and other biological materials. The objective of this study has been to develop a reliable and practical method for ICP-AES to estimate the serum concentrations of Zn, Cu, Fe, Mg, Ca, Na and K. 60 serum specimens were analyzed by both ICP-AES and Atomic Absorption Spectroscopy (AAS). The results were compared by the t-test and linear regression analysis. In comparison to the AAS method, the ICP-AES yields slightly higher Cu, Mg, Ca and K, and lower Zn, Fe and Na values. Except for Zn (r= 0.612), the correlation between the results is very high (³0.942), indicating that the ICP-AES results are equally satisfactory. In conclusion, ICP-AES is a reliable technique with the advantages of minimal sample volume and analysis time.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Inductively Coupled Plasma Atomic Emission Spectroscopy (ICP-AES), a modern technique with high sensitivity, accuracy and low matrix effect, is applied extensively in multielement analysis of serum and other biological materials. The objective of this study has been to develop a reliable and practical method for ICP-AES to estimate the serum concentrations of Zn, Cu, Fe, Mg, Ca, Na and K. 60 serum specimens were analyzed by both ICP-AES and Atomic Absorption Spectroscopy (AAS). The results were compared by the t-test and linear regression analysis. In comparison to the AAS method, the ICP-AES yields slightly higher Cu, Mg, Ca and K, and lower Zn, Fe and Na values. Except for Zn (r= 0.612), the correlation between the results is very high (³0.942), indicating that the ICP-AES results are equally satisfactory. In conclusion, ICP-AES is a reliable technique with the advantages of minimal sample volume and analysis time.

Key concepts: Inductively coupled plasma atomic emission spectroscopy, Atomic absorption spectroscopy, Inductively coupled plasma, Atomic emission spectroscopy, Analytical Chemistry (journal), Spectroscopy, Atomic spectroscopy, Matrix (chemical analysis)

Related papers

Back to paper searchBrowse research topicsOriginal source
Elemental Analysis of Serum by Inductively Coupled Plasma Atomic Emission Spectroscopy in Comparison to Atomic Absorption Spectroscopy — Research Paper | ScholarLens