[A chlorotetracycline fluorescent probe--an indicator of calcium ion binding with calcium-binding proteins].
V. P. Nikitin, Samoĭlov Mo
Abstract
V. P. Nikitin, Samoĭlov Mo
Abstract
It has been found in in vitro experiments that fluorescence intensity of deionized solution containing a chlorotetracycline fluorescent probe increases insignificantly at the addition of calmodulin of S-100 proteins. Subsequent introduction of Ca2+ into the medium results in the pronounced fluorescence increase depending on Ca2+ concentration. Addition of specific protein blockers--W7 (calmodulin inhibitor) and antibodies to S-100 brought about a decrease of fluorescence. In in vivo experiments on chlorotetracycline-stained neurons of Helix Pomatia ganglia subesophageal complex it has been shown that bringing of antibodies to S-100 and calmodulin significantly decreases the fluorescence intensity of these cells. These data suggest that the chlorotetracycline probe is an indicator of calcium ions binding with calcium-binding proteins both in in vitro and in vivo systems.
OpenAlex reports 9 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
It has been found in in vitro experiments that fluorescence intensity of deionized solution containing a chlorotetracycline fluorescent probe increases insignificantly at the addition of calmodulin of S-100 proteins. Subsequent introduction of Ca2+ into the medium results in the pronounced fluorescence increase depending on Ca2+ concentration. Addition of specific protein blockers--W7 (calmodulin inhibitor) and antibodies to S-100 brought about a decrease of fluorescence. In in vivo experiments on chlorotetracycline-stained neurons of Helix Pomatia ganglia subesophageal complex it has been shown that bringing of antibodies to S-100 and calmodulin significantly decreases the fluorescence intensity of these cells. These data suggest that the chlorotetracycline probe is an indicator of calcium ions binding with calcium-binding proteins both in in vitro and in vivo systems.
Key concepts: Calmodulin, Helix pomatia, Calcium, Fluorescence, In vivo, Chemistry, In vitro, Calcium-binding protein