2000PubMedRequires access

Fontanelle sizes in term neonates in Ibadan, Nigeria.

Adebowale Adeyemo, J A Olowu, O O Omotade

Open publisher page 9 citations

Abstract

Fontanelle sizes were studied in 200 term and appropriate-for-gestational age neonates delivered at the University College Hospital, Ibadan, Nigeria with the aim of determining their normal range of variation. The anterior and posterior fontanelle sizes were described using the range, mean, standard deviation and selected (3rd, 25th, 50th, 75th and 97th) percentiles. The anterior fontanelle size ranged from 1.0 to 6.4 cm with a mean of 4.0 (SD 1.0) cm. The posterior fontanelle size ranged from 0.0 to 5.5 cm with a mean of 1.4 (SD 1.7) cm. The posterior fontanelle was not palpable in 99 (49.5%) of the neonates and there was no association between the sex of the neonate and posterior fontanelle closure (X2 = 0.97, p = 0.325). The findings of the study are consistent with those of other workers who have documented larger anterior fontanelle sizes in the Negro neonate compared to his caucasian counterpart. However, the anterior fontanelle size in this study was larger than previously reported Nigerian figures, a fact which may be due to the exclusion of neonates who still had overriding cranial bones (from excessive moulding) at the time the measurements were taken. It is suggested that local values derived from well-defined populations be used as reference in the evaluation of the child with dysmorphic features in order to avoid errors of classification due to racial differences in the normal range of variation. Further studies of this nature are needed in order to delineate such differences where they exist.

About this research paper

What this paper is about

Fontanelle sizes were studied in 200 term and appropriate-for-gestational age neonates delivered at the University College Hospital, Ibadan, Nigeria with the aim of determining their normal range of variation. The anterior and posterior fontanelle sizes were described using the range, mean, standard deviation and selected (3rd, 25th, 50th, 75th and 97th) percentiles. The anterior fontanelle size ranged from 1.0 to 6.4 cm with a mean of 4.0 (SD 1.0) cm. The posterior fontanelle size ranged from 0.0 to 5.5 cm with a mean of 1.4 (SD 1.7) cm. The posterior fontanelle was not palpable in 99 (49.5%) of the neonates and there was no association between the sex of the neonate and posterior fontanelle closure (X2 = 0.97, p = 0.325). The findings of the study are consistent with those of other workers who have documented larger anterior fontanelle sizes in the Negro neonate compared to his caucasian counterpart. However, the anterior fontanelle size in this study was larger than previously reported Nigerian figures, a fact which may be due to the exclusion of neonates who still had overriding cranial bones (from excessive moulding) at the time the measurements were taken. It is suggested that local values derived from well-defined populations be used as reference in the evaluation of the child with dysmorphic features in order to avoid errors of classification due to racial differences in the normal range of variation. Further studies of this nature are needed in order to delineate such differences where they exist.

Why it matters

OpenAlex reports 9 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Fontanelle sizes were studied in 200 term and appropriate-for-gestational age neonates delivered at the University College Hospital, Ibadan, Nigeria with the aim of determining their normal range of variation. The anterior and posterior fontanelle sizes were described using the range, mean, standard deviation and selected (3rd, 25th, 50th, 75th and 97th) percentiles. The anterior fontanelle size ranged from 1.0 to 6.4 cm with a mean of 4.0 (SD 1.0) cm. The posterior fontanelle size ranged from 0.0 to 5.5 cm with a mean of 1.4 (SD 1.7) cm. The posterior fontanelle was not palpable in 99 (49.5%) of the neonates and there was no association between the sex of the neonate and posterior fontanelle closure (X2 = 0.97, p = 0.325). The findings of the study are consistent with those of other workers who have documented larger anterior fontanelle sizes in the Negro neonate compared to his caucasian counterpart. However, the anterior fontanelle size in this study was larger than previously reported Nigerian figures, a fact which may be due to the exclusion of neonates who still had overriding cranial bones (from excessive moulding) at the time the measurements were taken. It is suggested that local values derived from well-defined populations be used as reference in the evaluation of the child with dysmorphic features in order to avoid errors of classification due to racial differences in the normal range of variation. Further studies of this nature are needed in order to delineate such differences where they exist.

Key concepts: Anterior fontanelle, Fontanelle, Medicine, Percentile, Pediatrics, Surgery, Statistics, Mathematics

Related papers

Back to paper searchBrowse research topicsOriginal source
Fontanelle sizes in term neonates in Ibadan, Nigeria. — Research Paper | ScholarLens