1963•OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)Requires access

USE OF VORTEX TUBE FOR COOLING WEARERS OF INDUSTRIAL PROTECTIVE CLOTHING

John M. Alexander, J. J. Croley, R.R. Messick

Open publisher page 2 citations

Abstract

A Ranque-Hilsch vortex tube worn as a portable refrigerator can satisfactorily cool compressed air for personnel wearing industrial protective clothing. The vortex tube described was modified to meet Savannah River Plant specifications; it is light and small, and can be strapped to the body where it does not interfere with physical movements. The tube operates on 20 to 25 cfm of compressed air at 80 to 100 psig and delivers from 15 to 18 cfm of air cooled 50 to 80 deg F below the inlet air temperature. (auth)

About this research paper

What this paper is about

A Ranque-Hilsch vortex tube worn as a portable refrigerator can satisfactorily cool compressed air for personnel wearing industrial protective clothing. The vortex tube described was modified to meet Savannah River Plant specifications; it is light and small, and can be strapped to the body where it does not interfere with physical movements. The tube operates on 20 to 25 cfm of compressed air at 80 to 100 psig and delivers from 15 to 18 cfm of air cooled 50 to 80 deg F below the inlet air temperature. (auth)

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A Ranque-Hilsch vortex tube worn as a portable refrigerator can satisfactorily cool compressed air for personnel wearing industrial protective clothing. The vortex tube described was modified to meet Savannah River Plant specifications; it is light and small, and can be strapped to the body where it does not interfere with physical movements. The tube operates on 20 to 25 cfm of compressed air at 80 to 100 psig and delivers from 15 to 18 cfm of air cooled 50 to 80 deg F below the inlet air temperature. (auth)

Key concepts: Vortex tube, Compressed air, Tube (container), Clothing, Vortex, Inlet, Environmental science, Refrigerator car

Related papers

Back to paper searchBrowse research topicsOriginal source
USE OF VORTEX TUBE FOR COOLING WEARERS OF INDUSTRIAL PROTECTIVE CLOTHING — Research Paper | ScholarLens