2013•PubMedRequires access

[Finite element analysis of first maxillary molars restored with different post and core materials].

Li Zhao, Lijun Li, Ke Zhao, Xuliang Deng

Open publisher page 4 citations

Abstract

PURPOSE: To analyze the stress magnitude and distribution of residual dentin in maxillary first molar restored with post and crown using three-dimension finite element methods. METHODS: An intact maxillary first molar was scanned using a 3DX multi-image micro-CT. Three-dimensional finite element models simulated an endodontically treated first maxillary molar restored with post and crown, which were varied in different number and material of post. A load of 480 N, simulating intercuspal occlusion, was applied vertically to the occlusal surface and a load of 240 N simulating mastication was applied to the occlusal surface with a 45° angle to the long axis of the tooth. Von Mises stresses were calculated by MSC.Marc software. RESULTS: The maximum stresses among the post in the radicular portion increased as elastic modulus of the material increased. The stress values of remaining dentin observed in two-post group were lower than those in one post group and three-post group for cast metal post systems. In the test simulating mastication, the peak value of Von Mises stress was higher on remaining dentin among the post in the radicular portion and lower on the outer surface of residual tooth tissue than that in the test simulating intercuspal occlusion. CONCLUSIONS: The number, material of post and occlusal loading have influence on magnitude and distributionn of stress. Supported by Natural Science Foundation of China (81271175) and National Science and Technology Supporting Plan (2012BAI07B01).

About this research paper

What this paper is about

PURPOSE: To analyze the stress magnitude and distribution of residual dentin in maxillary first molar restored with post and crown using three-dimension finite element methods. METHODS: An intact maxillary first molar was scanned using a 3DX multi-image micro-CT. Three-dimensional finite element models simulated an endodontically treated first maxillary molar restored with post and crown, which were varied in different number and material of post. A load of 480 N, simulating intercuspal occlusion, was applied vertically to the occlusal surface and a load of 240 N simulating mastication was applied to the occlusal surface with a 45° angle to the long axis of the tooth. Von Mises stresses were calculated by MSC.Marc software. RESULTS: The maximum stresses among the post in the radicular portion increased as elastic modulus of the material increased. The stress values of remaining dentin observed in two-post group were lower than those in one post group and three-post group for cast metal post systems. In the test simulating mastication, the peak value of Von Mises stress was higher on remaining dentin among the post in the radicular portion and lower on the outer surface of residual tooth tissue than that in the test simulating intercuspal occlusion. CONCLUSIONS: The number, material of post and occlusal loading have influence on magnitude and distributionn of stress. Supported by Natural Science Foundation of China (81271175) and National Science and Technology Supporting Plan (2012BAI07B01).

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: To analyze the stress magnitude and distribution of residual dentin in maxillary first molar restored with post and crown using three-dimension finite element methods. METHODS: An intact maxillary first molar was scanned using a 3DX multi-image micro-CT. Three-dimensional finite element models simulated an endodontically treated first maxillary molar restored with post and crown, which were varied in different number and material of post. A load of 480 N, simulating intercuspal occlusion, was applied vertically to the occlusal surface and a load of 240 N simulating mastication was applied to the occlusal surface with a 45° angle to the long axis of the tooth. Von Mises stresses were calculated by MSC.Marc software. RESULTS: The maximum stresses among the post in the radicular portion increased as elastic modulus of the material increased. The stress values of remaining dentin observed in two-post group were lower than those in one post group and three-post group for cast metal post systems. In the test simulating mastication, the peak value of Von Mises stress was higher on remaining dentin among the post in the radicular portion and lower on the outer surface of residual tooth tissue than that in the test simulating intercuspal occlusion. CONCLUSIONS: The number, material of post and occlusal loading have influence on magnitude and distributionn of stress. Supported by Natural Science Foundation of China (81271175) and National Science and Technology Supporting Plan (2012BAI07B01).

Key concepts: Molar, Dentin, Materials science, von Mises yield criterion, Crown (dentistry), Mandibular first molar, Mastication, Maxillary first molar

Related papers

Back to paper searchBrowse research topicsOriginal source
[Finite element analysis of first maxillary molars restored with different post and core materials]. — Research Paper | ScholarLens