Suture Choice Matters in Rabbit Model of Laparoscopic, Preperitoneal, Inguinal Hernia Repair
Katherine B. Kelly, David M. Krpata, Jeffrey A. Blatnik, Todd A. Ponsky
Abstract
Katherine B. Kelly, David M. Krpata, Jeffrey A. Blatnik, Todd A. Ponsky
Abstract
PURPOSE: We evaluated the effect of different suture materials in a laparoscopic preperitoneal ligation of the patent processus vaginalis in a rabbit survival model. MATERIALS AND METHODS: New Zealand White rabbits underwent laparoscopic assisted preperitoneal ligation of the patent processus vaginalis. The processus vaginalis was closed with silk (n=10), polyglactin 910 (Vicryl(®); Ethicon, a Johnson & Johnson Company, Somerville, NJ) (n=10), or polypropylene (Prolene(®); Ethicon) (n=10). At necropsy, the suture was removed, and repair integrity was evaluated. RESULTS: All rabbits survived to necropsy without complications. No suture material was identified during necropsy of the Vicryl group. Eight (80%) of the Vicryl closures failed, with six (60%) failing at initial inspection. Following removal of suture material, nine (90%) of the Prolene closures failed, and only one (10%) of the silk closures failed (P=.009). CONCLUSIONS: The silk suture resulted in an improved closure rate. Ligation with silk suture probably incited an increased inflammatory response that likely created a scar while persisting long enough for the scar to become established. In contrast, the Vicryl sutures probably failed because the sutures dissolved before a scar was able to fully develop. Finally, the Prolene closures were suture dependent as evidenced by failure when the suture was removed. Nonabsorbable braided suture may improve closure of pediatric indirect inguinal hernias during laparoscopic-assisted preperitoneal ligation.
OpenAlex reports 23 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
PURPOSE: We evaluated the effect of different suture materials in a laparoscopic preperitoneal ligation of the patent processus vaginalis in a rabbit survival model. MATERIALS AND METHODS: New Zealand White rabbits underwent laparoscopic assisted preperitoneal ligation of the patent processus vaginalis. The processus vaginalis was closed with silk (n=10), polyglactin 910 (Vicryl(®); Ethicon, a Johnson & Johnson Company, Somerville, NJ) (n=10), or polypropylene (Prolene(®); Ethicon) (n=10). At necropsy, the suture was removed, and repair integrity was evaluated. RESULTS: All rabbits survived to necropsy without complications. No suture material was identified during necropsy of the Vicryl group. Eight (80%) of the Vicryl closures failed, with six (60%) failing at initial inspection. Following removal of suture material, nine (90%) of the Prolene closures failed, and only one (10%) of the silk closures failed (P=.009). CONCLUSIONS: The silk suture resulted in an improved closure rate. Ligation with silk suture probably incited an increased inflammatory response that likely created a scar while persisting long enough for the scar to become established. In contrast, the Vicryl sutures probably failed because the sutures dissolved before a scar was able to fully develop. Finally, the Prolene closures were suture dependent as evidenced by failure when the suture was removed. Nonabsorbable braided suture may improve closure of pediatric indirect inguinal hernias during laparoscopic-assisted preperitoneal ligation.
Key concepts: Vicryl, Prolene, Medicine, Fibrous joint, Surgery, Absorbable suture, Ligation, Hernia