2004Journal of Veterinary ScienceOpen access

TaqMan reverse transcription polymerase chain reaction for the detection of Japanese encephalitis virus

Dong Kun Yang, Chang Hee Kweon, Byoung Han Kim, Seong In Lim, Seong Hee Kim, Jun Kwon, Hong Han

Open full text 59 citations

Abstract

One step TaqMan reverse transcription polymerase chain reaction (RT-PCR) using TaqMan probe was developed for detection of Japanese encephalitis virus (JEV). Real-time RT-PCR was optimized to quantify JEV using the detection system (Rotor Gene 2000 detector) and dual-labeled fluorogenic probes. The gene specific labeled fluorogenic probe for the 3' non-translated region (3' NTR) was used to detect JEV. When the specificity of the assay using specific JEV primers was evaluated by testing three different JEV strains, other swine viruses and bovine viral diarrhea virus, no cross-reactions were detected with non-JE reference viruses. A single tube TaqMan assay was shown to be 10-fold more sensitive than the conventional two-step RT-PCR method. Detection limits of two step and real-time RT-PCR for JEV were 112 TCID(50) /ml and 11.2 TCID(50) /ml, respectively. Quantification of JEV was accomplished by a standard curve plotting cycle threshold values (C(t)) versus infectivity titer. Real-time RT-PCR assay using single tube method could be used as a sensitive diagnostic test, and supplied the results in real time for detection and quantification of JEV. We could detect JEV RNA genome in plasma samples of pigs inoculated with KV1899 strain at 2 days post inoculation, but couldn't in 41 fetus samples. This assay was sensitive, specific, rapid and quantitative for the detection of JEV from laboratory and field samples.

About this research paper

What this paper is about

One step TaqMan reverse transcription polymerase chain reaction (RT-PCR) using TaqMan probe was developed for detection of Japanese encephalitis virus (JEV). Real-time RT-PCR was optimized to quantify JEV using the detection system (Rotor Gene 2000 detector) and dual-labeled fluorogenic probes. The gene specific labeled fluorogenic probe for the 3' non-translated region (3' NTR) was used to detect JEV. When the specificity of the assay using specific JEV primers was evaluated by testing three different JEV strains, other swine viruses and bovine viral diarrhea virus, no cross-reactions were detected with non-JE reference viruses. A single tube TaqMan assay was shown to be 10-fold more sensitive than the conventional two-step RT-PCR method. Detection limits of two step and real-time RT-PCR for JEV were 112 TCID(50) /ml and 11.2 TCID(50) /ml, respectively. Quantification of JEV was accomplished by a standard curve plotting cycle threshold values (C(t)) versus infectivity titer. Real-time RT-PCR assay using single tube method could be used as a sensitive diagnostic test, and supplied the results in real time for detection and quantification of JEV. We could detect JEV RNA genome in plasma samples of pigs inoculated with KV1899 strain at 2 days post inoculation, but couldn't in 41 fetus samples. This assay was sensitive, specific, rapid and quantitative for the detection of JEV from laboratory and field samples.

Why it matters

OpenAlex reports 59 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

One step TaqMan reverse transcription polymerase chain reaction (RT-PCR) using TaqMan probe was developed for detection of Japanese encephalitis virus (JEV). Real-time RT-PCR was optimized to quantify JEV using the detection system (Rotor Gene 2000 detector) and dual-labeled fluorogenic probes. The gene specific labeled fluorogenic probe for the 3' non-translated region (3' NTR) was used to detect JEV. When the specificity of the assay using specific JEV primers was evaluated by testing three different JEV strains, other swine viruses and bovine viral diarrhea virus, no cross-reactions were detected with non-JE reference viruses. A single tube TaqMan assay was shown to be 10-fold more sensitive than the conventional two-step RT-PCR method. Detection limits of two step and real-time RT-PCR for JEV were 112 TCID(50) /ml and 11.2 TCID(50) /ml, respectively. Quantification of JEV was accomplished by a standard curve plotting cycle threshold values (C(t)) versus infectivity titer. Real-time RT-PCR assay using single tube method could be used as a sensitive diagnostic test, and supplied the results in real time for detection and quantification of JEV. We could detect JEV RNA genome in plasma samples of pigs inoculated with KV1899 strain at 2 days post inoculation, but couldn't in 41 fetus samples. This assay was sensitive, specific, rapid and quantitative for the detection of JEV from laboratory and field samples.

Key concepts: TaqMan, Virology, Japanese encephalitis, Virus, Reverse transcription polymerase chain reaction, Real-time polymerase chain reaction, Biology, Molecular biology

Related papers

Back to paper searchBrowse research topicsOriginal source
TaqMan reverse transcription polymerase chain reaction for the detection of Japanese encephalitis virus — Research Paper | ScholarLens