[Optimal extraction of melampyrit from Euonymus fortunei by central composite design-response surface methodology].
Wenjun Wei, Yanping Liu
Abstract
Wenjun Wei, Yanping Liu
Abstract
OBJECTIVE: To optimize the process of extracting melampyrit from Euonymus fortunei by central composite design-response surface methodology. METHODS: The independent variables were the solvent fold and extractive time, and the dependent variable was the extraction rate of melampyrit from Euonymus fortunei. Then different mathematic models were used to estimate the relationship between the independent and dependent variables. The response surface methodology was used to optimize the process of extraction and the prediction was carried out through comparing the observed and predicted values. RESULTS: The regression coefficient of binomial fitting complex model was 0.9515, and the optimum conditions of extraction process were 12-fold volume of solvent, 1.5 hours for decoction and 2 times for extraction. The bias between the observed and predicted values was -5.37%. CONCLUSION: It shows that this method is convenient and the optimum model is highly predictive.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
OBJECTIVE: To optimize the process of extracting melampyrit from Euonymus fortunei by central composite design-response surface methodology. METHODS: The independent variables were the solvent fold and extractive time, and the dependent variable was the extraction rate of melampyrit from Euonymus fortunei. Then different mathematic models were used to estimate the relationship between the independent and dependent variables. The response surface methodology was used to optimize the process of extraction and the prediction was carried out through comparing the observed and predicted values. RESULTS: The regression coefficient of binomial fitting complex model was 0.9515, and the optimum conditions of extraction process were 12-fold volume of solvent, 1.5 hours for decoction and 2 times for extraction. The bias between the observed and predicted values was -5.37%. CONCLUSION: It shows that this method is convenient and the optimum model is highly predictive.
Key concepts: Response surface methodology, Central composite design, Extraction (chemistry), Mathematics, Chromatography, Decoction, Biological system, Statistics